Question 1 · F – Performs preventative and predictive maintenance, commissioning and decommissioning
A fan shows high vibration at 1× running speed, mostly in the radial direction, with low axial vibration and steady phase. What is the most likely cause?
Show answer without guessing
Answer: C. Rotor unbalance, such as uneven dirt build-up on the blades
Unbalance produces a strong radial 1× peak with relatively low axial vibration. Misalignment usually shows high axial vibration and 2× components; bearing defects appear at non-synchronous frequencies; gear problems appear at gear mesh frequency. Cleaning and balancing the rotor is the usual fix.
Check it: RSOS task F-23
Question 2 · F – Performs preventative and predictive maintenance, commissioning and decommissioning
A 23-tooth pinion turns at 1,800 rpm. What is its gear mesh frequency?
Show answer without guessing
Answer: D. 690 Hz
Gear mesh frequency = number of teeth × shaft speed in revolutions per second = 23 × (1,800 ÷ 60) = 23 × 30 = 690 Hz. 41,400 is the same product in cycles per minute, which must be divided by 60 to get hertz.
Check it: RSOS task F-23
Question 3 · F – Performs preventative and predictive maintenance, commissioning and decommissioning
What does the grade ISO VG 68 on a lubricating oil indicate?
Show answer without guessing
Answer: B. Kinematic viscosity of about 68 mm²/s (cSt) at 40 °C
ISO viscosity grades classify industrial oils by their midpoint kinematic viscosity in mm²/s (centistokes) at 40 °C. Engine oils use the separate SAE system, and greases are graded for consistency by NLGI numbers, which run from 000 to 6.
Check it: RSOS task F-23
Question 4 · F – Performs preventative and predictive maintenance, commissioning and decommissioning
A new motor has been set on a pump base. Before it is coupled to the pump, what should be confirmed with the motor uncoupled?
Show answer without guessing
Answer: C. Direction of rotation, by bumping the motor briefly
Running a pump backward can loosen threaded impellers or damage seals, so rotation is checked with the motor uncoupled and the area clear. Hot alignment can only be checked after the machines run together at operating temperature.
Check it: RSOS task F-24
Question 5 · F – Performs preventative and predictive maintenance, commissioning and decommissioning
Before starting a newly installed gear reducer for the first time, what must be checked?
Show answer without guessing
Answer: B. That it is filled with the specified lubricant to the correct level
Many reducers ship without oil or with a preservative. They must be filled with the correct grade and quantity, and shipping plugs replaced with the breather. Starting a dry reducer can destroy gears and bearings in minutes.
Check it: RSOS task F-24
Question 6 · F – Performs preventative and predictive maintenance, commissioning and decommissioning
Why is a new hydraulic or lubrication system flushed before it is put into service?
Show answer without guessing
Answer: C. To remove contamination from fabrication and assembly before it damages components
New piping and components contain weld slag, scale, sealant and dirt. High-velocity flushing with temporary filters removes them until the cleanliness target is reached. Valves and sensitive components are often bypassed during flushing.
Check it: RSOS task F-24
Question 7 · F – Performs preventative and predictive maintenance, commissioning and decommissioning
A vibration spectrum shows many harmonics of running speed (1×, 2×, 3×, 4× and higher) with a raised noise floor. What does this usually indicate?
Show answer without guessing
Answer: A. Mechanical looseness, such as loose bolts or a worn fit
Looseness lets parts rattle and impact, producing a series of running-speed harmonics and sometimes half-harmonics. Check hold-down bolts, bearing fits, cracked bases and soft foot. Correcting looseness often reduces several other readings too.
Check it: RSOS task F-23
Question 8 · F – Performs preventative and predictive maintenance, commissioning and decommissioning
How is a bump (impact) test used in vibration troubleshooting?
Show answer without guessing
Answer: B. The stopped structure is struck and its response measured to find natural frequencies
Striking a structure excites its natural frequencies, which show as peaks in the response. If a natural frequency is close to running speed or another forcing frequency, resonance is likely, and stiffness or mass changes may be needed.
Check it: RSOS task F-23
Question 9 · F – Performs preventative and predictive maintenance, commissioning and decommissioning
Why should two greases with different thickener types not be mixed in a bearing without checking compatibility?
Show answer without guessing
Answer: D. Some thickeners are incompatible and the mixture can soften, harden or separate
Greases are made with thickeners such as lithium complex, polyurea, calcium sulfonate or clay. Some combinations break down, bleed oil or harden. When changing grease types, purge the old grease or confirm compatibility with the supplier.
Check it: RSOS task F-23
Question 10 · F – Performs preventative and predictive maintenance, commissioning and decommissioning
A bearing temperature is trended weekly. Which pattern most clearly calls for investigation?
Show answer without guessing
Answer: A. A steady rise above normal while load and ambient stay unchanged
Comparing a bearing's temperature with its own history and with ambient and load shows abnormal change. A rise not explained by operating conditions suggests lubrication, alignment or bearing problems, and vibration or ultrasound can confirm the cause.
Check it: RSOS task F-23
These are VoltExam questions written for the Red Seal Industrial Mechanic (Millwright) Interprovincial Exam, not official exam questions. Take the full free practice test or read the Red Seal Industrial Mechanic (Millwright) (433A) guide.
Last checked against Red Seal Program (with provincial and territorial apprenticeship authorities) on .
Practise Red Seal Industrial Mechanic (Millwright) (433A) by topic
Want every Red Seal Industrial Mechanic (Millwright) (433A) topic and the timed mock exams?
- ✓ 600 Red Seal Industrial Mechanic (Millwright) practice questions, every answer explained and cited
- ✓ Full-length timed mock exams: 135 questions, 4 hours, scored against 70%
- ✓ Practise by topic and review every question you missed
- ✓ Every other Canadian exam on VoltExam included
From
C$8.99/month
3-day free trial · or C$44.99 once for lifetime
Try all 600 free for 3 daysFree trial for new members on the Monthly plan, then C$8.99/month until you cancel. See all plans
Official sources
- Red Seal – Industrial Mechanic (Millwright) trade page ↗
- Red Seal – Industrial Mechanic (Millwright) exam information (breakdown) ↗
- Red Seal – Industrial Mechanic (Millwright) occupational standard for current exams ↗
- Red Seal – Industrial Mechanic (Millwright) occupational standard (new) ↗
- Red Seal – Exam Preparation Guide ↗
- Red Seal – Industrial Mechanic (Millwright) self-assessment tool (PDF) ↗
- Skilled Trades Ontario – Industrial Mechanic Millwright (433A) ↗
Sources checked November 14, 2026. VoltExam is independent and not affiliated with Red Seal Program (with provincial and territorial apprenticeship authorities). Rules change: confirm details with the official source before your exam.