Practice by topic · No signup
Ontario Working at Heights: Anchor points practice questions
9 original questions on this part of the exam, each with an explanation and a reference you can check.
What this area covers
Practical. What an anchor point is, permanent anchors versus temporary fixed supports and existing structures, the s. 26.7 strength ratings, suitable and unsuitable anchors, horizontal lifeline design rules, and getting information before using new anchors.
Question 1 · Anchor points
A temporary fixed support is used in a fall arrest system that includes a shock absorber. What static force must it be able to support?
Show answer without guessing
Answer: B. At least 6 kilonewtons
Section 26.7 (2) requires 8 kN for a fall arrest support, reduced to 6 kN when a shock absorber is used. Travel restraint supports need at least 2 kN, and fall restricting supports 6 kN unless used under the manufacturer's written instructions.
Check it: O. Reg. 213/91, s. 26.7 (2)
Question 2 · Anchor points
What minimum static force must a temporary fixed support used for a travel restraint system be able to support?
Show answer without guessing
Answer: B. 2 kilonewtons
A travel restraint support needs at least 2 kN because it only has to hold the worker back from the edge, not stop a fall. Fall arrest supports need 8 kN (or 6 kN with a shock absorber).
Check it: O. Reg. 213/91, s. 26.7 (2), para. 5
Question 3 · Anchor points
Which requirement applies to a horizontal lifeline system on an Ontario construction project?
Show answer without guessing
Answer: D. An engineer designs it and the design states how many workers can safely attach
Section 26.9 (8) requires an engineered design showing the arrangement, components, number of workers, installation instructions and design loads. It must be inspected before each use and the constructor keeps the design at the project.
Check it: O. Reg. 213/91, s. 26.9 (8)
Question 4 · Anchor points
What is an anchor point in a fall protection system?
Show answer without guessing
Answer: C. A secure attachment point for a lifeline, lanyard or other connector
An anchor (fixed support) is the attachment point that connects the worker's system to the structure. It must be strong enough for the forces involved.
Check it: WAH Program Standard, Anchor points; O. Reg. 213/91, s. 1 (1) "fixed support"
Question 5 · Anchor points
Which of these is generally NOT a suitable anchor for fall arrest?
Show answer without guessing
Answer: A. A plumbing vent pipe on the roof
Vent pipes, conduit, ductwork and similar features are not designed for fall arrest forces. Suitable anchors are engineered or verified to meet the required capacity.
Check it: WAH Program Standard, Anchor points; O. Reg. 213/91, s. 26.7
Question 6 · Anchor points
Who must inspect a horizontal lifeline system before each use?
Show answer without guessing
Answer: B. An engineer, or a competent worker designated by a supervisor
Section 26.9 (8) requires inspection before each use by an engineer or a competent worker designated by a supervisor.
Check it: O. Reg. 213/91, s. 26.9 (8), para. 5
Question 7 · Anchor points
Why is anchoring to a guardrail top rail not acceptable for fall arrest?
Show answer without guessing
Answer: B. The guardrail is not designed for fall arrest loads and could fail
Guardrails are built for the s. 26.3 (5) loads (such as 675 N lateral), much less than the 6-8 kN anchor requirement for fall arrest in s. 26.7 (2).
Check it: O. Reg. 213/91, ss. 26.3 (5), 26.7 (2)
Question 8 · Anchor points
What is the danger of choosing an anchor far to the side of the work position?
Show answer without guessing
Answer: D. A fall can become a swing that strikes nearby objects or the ground
Anchors that are off to the side create swing (pendulum) falls. Anchors should be as directly overhead as practicable.
Check it: WAH Program Standard, Anchor points; Personal fall protection equipment
Question 9 · Anchor points
A suspended work platform lifeline subject to wind hangs 120 m below its fixed support. What else is required?
Show answer without guessing
Answer: B. It must be restrained at or near its midpoint
Section 142.06 (3) (d) (ii) requires lifelines suspended more than 100 m below the fixed support to be restrained at or near the midpoint when subject to wind.
Check it: O. Reg. 213/91, s. 142.06 (3) (d)
These are VoltExam questions written for the Ontario Working at Heights Training Test (CPO-Approved Program), not official exam questions. Take the full free practice test or read the Ontario Working at Heights guide.
Last checked against Ontario Ministry of Labour, Immigration, Training and Skills Development (Chief Prevention Officer) on .
Practise Ontario Working at Heights by topic
- Roles, rights and responsibilities
- Hazards of working at heights
- Eliminating or controlling fall hazards
- Warning methods and physical barriers
- Barriers and other fixed equipment
- Ladders and similar equipment
- Fall protection systems
- Personal fall protection equipment
- Work access equipment and platforms
- Rescue planning
Want every Ontario Working at Heights topic and the timed mock exams?
- ✓ 600 Ontario Working at Heights practice questions, every answer explained and cited
- ✓ Full-length timed mock exams: 40 questions, 1 hours, scored against 75%
- ✓ Practise by topic and review every question you missed
- ✓ Every other Canadian exam on VoltExam included
From
C$8.99/month
3-day free trial · or C$44.99 once for lifetime
Try all 600 free for 3 daysFree trial for new members on the Monthly plan, then C$8.99/month until you cancel. See all plans
Official sources
- Ontario: Training for working at heights ↗
- Ontario: Working at heights training program standard ↗
- Ontario: Working at heights training provider standard ↗
- e-Laws: O. Reg. 297/13 Occupational Health and Safety Awareness and Training ↗
- e-Laws: O. Reg. 213/91 Construction Projects ↗
- e-Laws: Occupational Health and Safety Act, R.S.O. 1990, c. O.1 ↗
Sources checked November 3, 2026. VoltExam is independent and not affiliated with Ontario Ministry of Labour, Immigration, Training and Skills Development (Chief Prevention Officer). Rules change: confirm details with the official source before your exam.